The SIMATIC Drive Controller supports isochronous mode for the following clock systems:
PROFINET IO interface X150
PROFIBUS DP interface X126
Technology I/Os X142
With PROFIdrive Integrated
You can operate the clock systems separately or coupled on an isochronous basis. Exception: Isochronous coupling of the PROFIBUS DP interface is not possible. You can find information on the combinations in which you can couple the clock systems in Overview of isochronous mode.
You make the required settings in the relevant clock systems.
Once you have set and, if necessary, coupled the clock systems, you need to couple the OB servo with the clock system in which you wish to operate the drives / that is the leading clock system.
Proceed as follows to set the clock system of the SINAMICS Integrated:
Switch to the network view.
Click on PROFIdrive Integrated in the network view.
Make the settings for the SINAMICS Integrated under "Constant bus cycle time".
The SINAMICS Integrated is always isochronous (option is always selected).
圖片: SINAMICS Integrated (PROFIdrive Integrated) clock system
Adjust other settings if required – for example times Ti/To for reading in/outputting data in isochronous mode.
列表: Setting options for "Cycle time" in the SINAMICS Integrated clock system
Setting options | Note |
---|---|
Manual | With these settings, you operate the SINAMICS Integrated as an independent clock system. |
Automatic minimum | |
Use local send clock [X142] | With this setting, you operate the SINAMICS Integrated in isochronous mode coupled with the clock system of the X142 technology I/Os. Use this setting if you want to use the technology I/Os isochronously with the OB servo, for example, for measuring input or output cam applications. Please note the following: You cannot operate the X142 technology I/Os in isochronous mode separately from SINAMICS Integrated. If you want to operate X142 technology I/Os and SINAMICS Integrated in isochronous mode simultaneously, always set coupled isochronous mode. Consistency checks ensure that the setting is correct. |
Send clock of the PROFINET interface [X150] | With this setting, you operate SINAMICS Integrated in isochronous mode coupled with PROFINET interface X150. SINAMICS Integrated uses the system clock of PROFINET interface X150. Use this setting if you need to operate the SIMATIC Drive Controller in isochronous mode at PROFINET IO interface X150, for example, for the connection of drives or for synchronous operation across PLC. |
Proceed as follows to set the clock system of the X142 technology I/Os:
In the device view of STEP 7, select the CPU of the SIMATIC Drive Controller.
Navigate to "Advanced configuration" > "Isochronous mode" in the properties of the CPU.
Select the required settings from the "Source of send clock" drop-down list in the "Isochronous mode for local modules" section.
圖片: Technology I/O clock system
列表: Setting options for "Source of send clock" in the clock system of the technology I/Os
Setting options | Note |
---|---|
Local send clock | With this setting, you operate the X142 technology I/Os as an independent clock system, or as the leading clock system if you couple the clock system of the SINAMICS Integrated. |
Using the send clock of the PROFINET interface [X150] | With this setting, you operate X142 technology I/Os in isochronous mode coupled with PROFINET interface X150. The X142 technology I/Os use the system clock of PROFINET interface X150. |
Proceed as follows to set the clock system of PROFINET interface X150:
Select the PROFINET IO system in the network view of STEP 7.
Make the settings for the send clock, etc. under "PROFINET subnet" > "Domain management" > "Sync domains".
In coupled isochronous mode with other clock systems, the clock system of the PROFINET interface is always leading.
You can find additional information on configuring isochronous mode on PROFINET IO in the Isochronous mode function manual.
You must follow the rules below during configuration if you want to operate the PROFIBUS DP interface in isochronous mode:
列表: Rules for configuring isochronous mode for PROFIBUS DP interface
If ... | The configured cycle time of the PROFIBUS DP interface must... |
---|---|
A SINAMICS Integrated is configured | Be equal to or an integer multiple of the configured cycle time of the SINAMICS Integrated (PROFIdrive Integrated) |
The X142 technology I/Os are operated in isochronous mode | Be equal to or an integer multiple of the configured cycle time of the X142 technology I/Os |
The clock system of the PROFINET IO interface is coupled with one of the two clock systems. | Be equal to or an integer multiple of the configured cycle time of the PROFINET IO interface |
Consistency checks ensure that the setting is correct.
Proceed as follows to set the clock system of the PROFIBUS interface:
Select the DP master system in the network view of STEP 7.
Make the settings for the DP cycle under "Constant bus cycle time".
提示 Isochronous coupling of the PROFIBUS interface with other clock systems is not possible. If you want to expand the drive configuration limits with distributed drive systems, connect those distributed drive systems over the PROFINET IO interface X150. Only the PROFINET IO interface X150 can be connected isochronously alongside the MC Servo to the clock system of SINAMICS Integrated and the X142 technology I/Os. |
Proceed as follows to synchronize the MC Servo with a clock system:
Open the "Program blocks" folder in the project tree.
Select the "MC Servo" organization block.
Select the "Properties" command in the shortcut menu.
Select the "Cycle time" entry in the area navigation.
The option "Synchronous to the bus" must be selected in the dialog box.
In the "Source of send clock" drop-down list, select the clock system to be synchronized with the OB MC?Servo.
圖片: Synchronizing MC Servo with clock system
列表: Setting options for synchronization with a clock system
Setting options1) | Note |
---|---|
PROFIdrive system (1) | With this setting, you synchronize MC Servo with the clock system of SINAMICS Integrated. |
PROFINET IO system (100) | With this setting, you synchronize MC Servo with PROFINET interface X150. |
PLC_1 (0) | With this setting, you synchronize MC Servo with the clock system of technology I/Os X142. |
DP master system (2) | With this setting, you synchronize MC Servo with PROFIBUS interface X126. |
For coupled isochronous mode, you must always select the leading clock system.
The application cycle of MC Servo is derived from the send clock and a configurable factor. The adjustable factors depend on the coupled clock system.
詞條
詞條說明
ListGenerator1500/300/400 FCListGenerator FC 具有三個版本,其符號名稱如下:對于 S7-300ListGenerator300對于 S7-400ListGenerator400對于 S7-1500ListGenerator1500功能如果數(shù)據(jù)所包含的目標(biāo)地址不完整,或者根本不包含目標(biāo)地址,則在接收這樣的數(shù)據(jù)的 CPU 中,需要 FC ListGenera
軟件握手/硬件握手簡介用于控制兩個通信伙伴之間數(shù)據(jù)流的握手協(xié)議。 使用握手程序可以防止兩個設(shè)備以不同的傳輸率操作時在傳輸期間產(chǎn)生數(shù)據(jù)丟失。握手程序握手有兩種基本類型:軟件握手(例如 XON/XOFF)硬件握手(例如 RTS/CTS)在通信模塊上按照以下方式執(zhí)行數(shù)據(jù)流控制:一旦模塊通過組態(tài)切換到使用流控制的工作模式,模塊便會發(fā)送 XON 字符或?qū)?RTS 線路設(shè)置為 ON。如果在接收緩沖區(qū)溢出(接收
S7-200 SMART 與 S7-1200 之間 TCP 通信— S7-200 SMART 作為客戶端TCP 協(xié)議通信TCP 通信為面向連接的通信,需要雙方都調(diào)用指令以建立連接及交換數(shù)據(jù)。S7-200 SMART 與 S7-1200 通過 TCP 通信,在 S7-1200 調(diào)用 T-block 指令 ( TCON, TDISCON, TSEND, TRCV ) ,在 S7-200 SMART 調(diào)
ST 常規(guī)說明該頁面包含以下框:網(wǎng)橋**級 (Bridge Priority)?/?根**級 (Root Priority)(僅在線時可用)由網(wǎng)橋**級決定哪個設(shè)備成為根網(wǎng)橋。**級較高的網(wǎng)橋(換句話說,此參數(shù)的值較小)將成為根網(wǎng)橋。如果網(wǎng)絡(luò)中有多個設(shè)備具有相同**級,則 MAC 地址數(shù)值較小的設(shè)備將成為根網(wǎng)橋。網(wǎng)橋**級和 MAC 地址這兩個參數(shù)一起構(gòu)成網(wǎng)橋標(biāo)識符。由于根網(wǎng)橋
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
電 話: 021-37660026
手 機(jī): 13681875601
微 信: 13681875601
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
手 機(jī): 13681875601
電 話: 021-37660026
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com
¥6300.00
網(wǎng)課專享 教學(xué)一體機(jī) 21.5寸
¥1980.00