Setting the clock system

    Setting the clock system

    The SIMATIC Drive Controller supports isochronous mode for the following clock systems:

    PROFINET IO interface X150

    PROFIBUS DP interface X126

    Technology I/Os X142

    With PROFIdrive Integrated

    You can operate the clock systems separately or coupled on an isochronous basis. Exception: Isochronous coupling of the PROFIBUS DP interface is not possible. You can find information on the combinations in which you can couple the clock systems in Overview of isochronous mode.

    You make the required settings in the relevant clock systems.

    Once you have set and, if necessary, coupled the clock systems, you need to couple the OB servo with the clock system in which you wish to operate the drives / that is the leading clock system.

    SINAMICS Integrated clock system

    Proceed as follows to set the clock system of the SINAMICS Integrated:

      Switch to the network view.

      Click on PROFIdrive Integrated in the network view.

      Make the settings for the SINAMICS Integrated under "Constant bus cycle time".
      The SINAMICS Integrated is always isochronous (option is always selected).


      圖片: SINAMICS Integrated (PROFIdrive Integrated) clock system

      Adjust other settings if required – for example times Ti/To for reading in/outputting data in isochronous mode.

    列表: Setting options for "Cycle time" in the SINAMICS Integrated clock system

    Setting options

    Note

    Manual

    With these settings, you operate the SINAMICS Integrated as an independent clock system.

    Automatic minimum

    Use local send clock [X142]

    With this setting, you operate the SINAMICS Integrated in isochronous mode coupled with the clock system of the X142 technology I/Os.

    Use this setting if you want to use the technology I/Os isochronously with the OB servo, for example, for measuring input or output cam applications.

    Please note the following:

    You cannot operate the X142 technology I/Os in isochronous mode separately from SINAMICS Integrated.

    If you want to operate X142 technology I/Os and SINAMICS Integrated in isochronous mode simultaneously, always set coupled isochronous mode.

    Consistency checks ensure that the setting is correct.

    Send clock of the PROFINET interface [X150]

    With this setting, you operate SINAMICS Integrated in isochronous mode coupled with PROFINET interface X150. SINAMICS Integrated uses the system clock of PROFINET interface X150.

    Use this setting if you need to operate the SIMATIC Drive Controller in isochronous mode at PROFINET IO interface X150, for example, for the connection of drives or for synchronous operation across PLC.

    X142 technology I/Os clock system

    Proceed as follows to set the clock system of the X142 technology I/Os:

      In the device view of STEP 7, select the CPU of the SIMATIC Drive Controller.

      Navigate to "Advanced configuration" > "Isochronous mode" in the properties of the CPU.

      Select the required settings from the "Source of send clock" drop-down list in the "Isochronous mode for local modules" section.


      圖片: Technology I/O clock system

    列表: Setting options for "Source of send clock" in the clock system of the technology I/Os

    Setting options

    Note

    Local send clock

    With this setting, you operate the X142 technology I/Os as an independent clock system, or as the leading clock system if you couple the clock system of the SINAMICS Integrated.

    Using the send clock of the PROFINET interface [X150]

    With this setting, you operate X142 technology I/Os in isochronous mode coupled with PROFINET interface X150. The X142 technology I/Os use the system clock of PROFINET interface X150.

    PROFINET IO interface X150 clock system

    Proceed as follows to set the clock system of PROFINET interface X150:

      Select the PROFINET IO system in the network view of STEP 7.

      Make the settings for the send clock, etc. under "PROFINET subnet" > "Domain management" > "Sync domains".

    In coupled isochronous mode with other clock systems, the clock system of the PROFINET interface is always leading.

    You can find additional information on configuring isochronous mode on PROFINET IO in the Isochronous mode function manual.

    PROFIBUS interface X126 clock system

    You must follow the rules below during configuration if you want to operate the PROFIBUS DP interface in isochronous mode:

    列表: Rules for configuring isochronous mode for PROFIBUS DP interface

    If ...

    The configured cycle time of the PROFIBUS DP interface must...

    A SINAMICS Integrated is configured

    Be equal to or an integer multiple of the configured cycle time of the SINAMICS Integrated (PROFIdrive Integrated)

    The X142 technology I/Os are operated in isochronous mode

    Be equal to or an integer multiple of the configured cycle time of the X142 technology I/Os

    The clock system of the PROFINET IO interface is coupled with one of the two clock systems.

    Be equal to or an integer multiple of the configured cycle time of the PROFINET IO interface

    Consistency checks ensure that the setting is correct.

    Proceed as follows to set the clock system of the PROFIBUS interface:

      Select the DP master system in the network view of STEP 7.

      Make the settings for the DP cycle under "Constant bus cycle time".


    提示

    Isochronous coupling of the PROFIBUS interface with other clock systems is not possible.

    If you want to expand the drive configuration limits with distributed drive systems, connect those distributed drive systems over the PROFINET IO interface X150. Only the PROFINET IO interface X150 can be connected isochronously alongside the MC Servo to the clock system of SINAMICS Integrated and the X142 technology I/Os.



    Synchronizing MC Servo with clock system

    Proceed as follows to synchronize the MC Servo with a clock system:

      Open the "Program blocks" folder in the project tree.

      Select the "MC Servo" organization block.

      Select the "Properties" command in the shortcut menu.

      Select the "Cycle time" entry in the area navigation.

      The option "Synchronous to the bus" must be selected in the dialog box.

      In the "Source of send clock" drop-down list, select the clock system to be synchronized with the OB MC?Servo.


      圖片: Synchronizing MC Servo with clock system

    列表: Setting options for synchronization with a clock system

    Setting options1)

    Note

    PROFIdrive system (1)

    With this setting, you synchronize MC Servo with the clock system of SINAMICS Integrated.

    PROFINET IO system (100)

    With this setting, you synchronize MC Servo with PROFINET interface X150.

    PLC_1 (0)

    With this setting, you synchronize MC Servo with the clock system of technology I/Os X142.

    DP master system (2)

    With this setting, you synchronize MC Servo with PROFIBUS interface X126.

    1) The designations may vary depending on the names assigned.

    For coupled isochronous mode, you must always select the leading clock system.

    Setting the application cycle

    The application cycle of MC Servo is derived from the send clock and a configurable factor. The adjustable factors depend on the coupled clock system.


    上海騰希電氣技術(shù)有限公司專注于西門子PLC,V90伺服,V20變頻器等, 歡迎致電 13681875601

  • 詞條

    詞條說明

  • ListGenerator1500/300/400 FC

    ListGenerator1500/300/400 FCListGenerator FC 具有三個版本,其符號名稱如下:對于 S7-300ListGenerator300對于 S7-400ListGenerator400對于 S7-1500ListGenerator1500功能如果數(shù)據(jù)所包含的目標(biāo)地址不完整,或者根本不包含目標(biāo)地址,則在接收這樣的數(shù)據(jù)的 CPU 中,需要 FC ListGenera

  • 軟件握手/硬件握手

    軟件握手/硬件握手簡介用于控制兩個通信伙伴之間數(shù)據(jù)流的握手協(xié)議。 使用握手程序可以防止兩個設(shè)備以不同的傳輸率操作時在傳輸期間產(chǎn)生數(shù)據(jù)丟失。握手程序握手有兩種基本類型:軟件握手(例如 XON/XOFF)硬件握手(例如 RTS/CTS)在通信模塊上按照以下方式執(zhí)行數(shù)據(jù)流控制:一旦模塊通過組態(tài)切換到使用流控制的工作模式,模塊便會發(fā)送 XON 字符或?qū)?RTS 線路設(shè)置為 ON。如果在接收緩沖區(qū)溢出(接收

  • 與S7-1200之間TCP通信二

    S7-200 SMART 與 S7-1200 之間 TCP 通信— S7-200 SMART 作為客戶端TCP 協(xié)議通信TCP 通信為面向連接的通信,需要雙方都調(diào)用指令以建立連接及交換數(shù)據(jù)。S7-200 SMART 與 S7-1200 通過 TCP 通信,在 S7-1200 調(diào)用 T-block 指令 ( TCON, TDISCON, TSEND, TRCV ) ,在 S7-200 SMART 調(diào)

  • * 2 層功能 ST 常規(guī)

    ST 常規(guī)說明該頁面包含以下框:網(wǎng)橋**級 (Bridge Priority)?/?根**級 (Root Priority)(僅在線時可用)由網(wǎng)橋**級決定哪個設(shè)備成為根網(wǎng)橋。**級較高的網(wǎng)橋(換句話說,此參數(shù)的值較小)將成為根網(wǎng)橋。如果網(wǎng)絡(luò)中有多個設(shè)備具有相同**級,則 MAC 地址數(shù)值較小的設(shè)備將成為根網(wǎng)橋。網(wǎng)橋**級和 MAC 地址這兩個參數(shù)一起構(gòu)成網(wǎng)橋標(biāo)識符。由于根網(wǎng)橋

標(biāo)簽:Setting the clock system

聯(lián)系方式 聯(lián)系我時,請告知來自八方資源網(wǎng)!

公司名: 上海騰希電氣技術(shù)有限公司

聯(lián)系人: 田禮科

電 話: 021-37660026

手 機(jī): 13681875601

微 信: 13681875601

地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓

郵 編:

網(wǎng) 址: shtxjd.cn.b2b168.com

八方資源網(wǎng)提醒您:
1、本信息由八方資源網(wǎng)用戶發(fā)布,八方資源網(wǎng)不介入任何交易過程,請自行甄別其真實(shí)性及合法性;
2、跟進(jìn)信息之前,請仔細(xì)核驗(yàn)對方資質(zhì),所有預(yù)付定金或付款至個人賬戶的行為,均存在詐騙風(fēng)險,請?zhí)岣呔瑁?
    聯(lián)系方式

公司名: 上海騰希電氣技術(shù)有限公司

聯(lián)系人: 田禮科

手 機(jī): 13681875601

電 話: 021-37660026

地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓

郵 編:

網(wǎng) 址: shtxjd.cn.b2b168.com

    相關(guān)企業(yè)
    商家產(chǎn)品系列
  • 產(chǎn)品推薦
  • 資訊推薦
關(guān)于八方 | 八方幣 | 招商合作 | 網(wǎng)站地圖 | 免費(fèi)注冊 | 一元廣告 | 友情鏈接 | 聯(lián)系我們 | 八方業(yè)務(wù)| 匯款方式 | 商務(wù)洽談室 | 投訴舉報
粵ICP備10089450號-8 - 經(jīng)營許可證編號:粵B2-20130562 軟件企業(yè)認(rèn)定:深R-2013-2017 軟件產(chǎn)品登記:深DGY-2013-3594
著作權(quán)登記:2013SR134025
Copyright ? 2004 - 2024 b2b168.com All Rights Reserved