KCD2-SR-1.LB KCD2-SR-Ex1.LB.SP倍加福KCD2-SCD-Ex1 Switch Amplifier 1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SR-Ex1.LB Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SR-Ex2 Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-UT2-Ex1 Universal Temperature Converter 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511 KCD2-RR-Ex1 Resistance Repeater 1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system KCD0-SD3-Ex1.1245 Solenoid Driver 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD2-E2L 傳感器輸出接口端子 帶斷線檢測的單通道終端放大器、用于 NAMUR 傳感器的輸入、24 V DC 電源電壓、用于防止出現(xiàn)信號傳輸錯誤的標準化接口、開關狀態(tài)顯示屏、黃色 LED KCD2-EL 傳感器輸出接口端子 單通道端子放大器, NAMUR 傳感器輸入, 24 V 直流電源電壓, 用于防止信號傳輸錯誤的標準接口, 開關狀態(tài)指示燈,黃色 LED KCD2-R 傳感器輸出接口端子 單繼電器輸出,黃色 LED 指示開關狀態(tài), 續(xù)流二管, 緊湊的端子外殼, 夾到標準 35 mm 導軌上,符合 DIN EN 50 022 標準, 防護等級 IP20 KCD2-RR2-Ex1 Resistance Repeater 1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system KCD2-SCD-1 SMART Current Driver 1-channel ** conditioner, 24 V DC supply (Power Rail), Current output up to 900 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field KCD2-SCD-Ex1 SMART Current Driver 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field KCD2-SOT-Ex1.LB Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SOT-Ex2 Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SR-2 Switch Amplifier 2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-STC-1.2O SMART Transmitter Power Supply 1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508 KCD2-STC-Ex1 SMART Transmitter Power Supply 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-STC-Ex1.2O SMART Transmitter Power Supply 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508 KCD2-STC-Ex1.2O.ES SMART Transmitter Power Supply 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508 KCD2-STC-Ex1.ES SMART Transmitter Power Supply 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD2-UT2-1 Universal Temperature Converter 1-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511 KCD2-SOT-1.LB Switch Amplifier 1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-ST-Ex2 Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD0-LGH Place Holder Barrier IS K-System place holder module, Housing width 12.5 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers KCD0-RSH-1.1D.1 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849 KCD0-RSH-1.1D.4 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849 KCD0-RSH-1.1E.1 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508 KCD0-SD3-Ex1.1045 Solenoid Driver 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD0-SD3-Ex1.1245.SP Solenoid Driver 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Test pulse immunity, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508 KCD2-E1 傳感器輸出接口端子 單通道端子放大器, NAMUR 傳感器輸入, 24 V 直流電源電壓, 用于防止信號傳輸錯誤的標準接口, 開關狀態(tài)指示燈,黃色 LED KCD2-E3 傳感器輸出接口端子 單通道端子放大器, NAMUR 傳感器輸入, 24 V 直流電源電壓, 用于防止信號傳輸錯誤的標準接口, 開關狀態(tài)指示燈,黃色 LED KCD2-SCD-1.SP SMART Current Driver 1-channel ** conditioner, 24 V DC supply (Power Rail), Current output up to 900 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field KCD2-SCD-Ex1.SP SMART Current Driver 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field KCD2-SLD-Ex1.1045 Solenoid Driver 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD2-SLD-Ex1.1065 Solenoid Driver 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD2-SLD-Ex1.1245 Solenoid Driver 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508 KCD2-SON-Ex1 Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SON-Ex1.R2 Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as ** splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SON-Ex1.R3 Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as ** splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SON-Ex2 Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SON-Ex2.R1 Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SON-Ex2.R2 Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SON-Ex2.R3 Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SOT-2 Switch Amplifier 2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-SOT-Ex2.SP Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SR-1.LB.SP Switch Amplifier 1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SR-Ex1.LB.SP Switch Amplifier 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-SR-Ex2.SP Switch Amplifier 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KCD2-ST-1.LB Switch Amplifier 1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-ST-2 Switch Amplifier 2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
詞條
詞條說明
羅斯蒙特/艾默生3400HT/3400HTVP pH/0RP電3400HT-10-21-30-61
羅斯蒙特/艾默生3400HT/3400HTVP pH/0RP電 3400HT傳感器:2磅/3磅(0.9公斤/1.4公斤)-選型代碼21;3磅/4磅(1.4公斤/1.8公斤)-選型代碼25 3400HT-10-21-30-61 3400HT--12--21-31-61 3400HTVT-10-21--32 340HT-10-21-30-62 340HT-12-21-31-62 3400HTVP--
Rosemount? 245 衛(wèi)生型流通式環(huán)形電導率傳感器
Rosemount? 245 衛(wèi)生型流通式環(huán)形電導率傳感器 規(guī)格 環(huán)境溫度 低溫度:0 °C (32 °F) 高溫度:121 °C (250 °F) 持續(xù);130 °C (266 °F) 蒸汽中 45 分鐘 重量 4.5 kg (9 lb) 功能 ?的測量 – 對過程流量和方向不敏感 ?沒有部件伸入到樣品液流中,可避免固體積聚 ?有 0.5、1.0、1.5 和 2 英寸 Tri Clamp
型號:FCST-A4-NA/D100 10M圖爾克流量傳感器貨號:100002579圖爾克流量傳感器型號:FCS-G3/4A4-NAEX-H1141貨號:6870462圖爾克流量傳感器型號:FCS-G1/2HC4-NAEX0/L140/D024 5M貨號:6870394圖爾克流量傳感器型號:FCS-G1/4A4-NAEX/D100貨號:6870475圖爾克流量圖爾克型號:FCS-N1/2A4P-L
402VP-11 402-11 402-12-31-60 402-13-54-31 . 402-11-61 402-12-31-60-61 402- 13-54-31-61 402-11-60 402-12-54 402- 13-54-31-60 402-11-60-61 402-12-54-61 402- 13-54-31-60-61 402-11-31 402- 12-54-60 402-13
聯(lián)系人: 張曉龍
電 話: 18001664790
手 機: 18001664790
微 信: 18001664790
地 址: 上海松江方松辰塔路2號
郵 編:
網(wǎng) 址: chuangfusy.b2b168.com
聯(lián)系人: 張曉龍
手 機: 18001664790
電 話: 18001664790
地 址: 上海松江方松辰塔路2號
郵 編:
網(wǎng) 址: chuangfusy.b2b168.com