Configuring additional drives on PROFINET (X150) as isochronous

    Configuring additional drives on PROFINET (X150) as isochronous

    Requirement

    STEP 7, V16 or higher

    SINAMICS Startdrive, V16 or higher

    You can import drives that are not integrated in the TIA Portal via Startdrive using GSD files (generic station description). To do so, install the drive in the "Options" menu as a device description file (GSD).

    Adding a drive and frame to the device configuration

      Add the required drive system in the network view, for example, SINAMICS S120 CU320-2 PN.

      Open the device view of the drive system and configure the drive objects.
      You can find the relevant details in the SINAMICS S120 with Startdrive commissioning manual.

      Open the network view. Assign the drive system to the PROFINET interface [X150] of the CPU.

      Open the topology view. Interconnect the port of the drive system as in the real configuration with the port of the CPU.

      Configure the PROFIdrive frames for the drive axes, for example, frame 105.


    提示

    If you use a PROFINET IO drive system other than SINAMICS S120, adding and configuring may differ from the description in certain respects. The frame is automatically preassigned in line with the drive system.



    Activating isochronous mode in the device configuration

    You can operate PROFINET drives in isochronous or non-isochronous mode. Isochronous mode, however, increases the quality of the position control of the drive and is therefore recommended for drives such as SINAMICS S120.

    Proceed as follows to activate isochronous mode for the drive:

      Select the device view of the drive system.

      In the properties window, select the tab "PROFINET Interface [X150]" > "Advanced options" > "Isochronous mode".

      Select the "Isochronous mode" check box.

      In the properties window, select the tab "PROFINET Interface [150]" > "Advanced options" > "Real-time settings" > "Synchronization".

      Select "IRT" as the RT class.


    提示

    If you have configured a PROFIdrive frame at the drive that requires isochronous mode, STEP 7 automatically sets "Isochronous mode" and the RT class "IRT".



    Configuring the PLC as sync master and setting the send clock

      Select the device view of the CPU.

      In the properties window, select the tab "PROFINET interface [X150]" > "Advanced options" > "Real-time settings" > "Synchronization".

      Select "IRT" as the RT class if it has not already been set automatically.

      Select "Sync master" from the "Synchronization role" drop-down list.

      Click the "Domain settings" button.

      Set the required send clock.

    Selecting the drive in the configuration of the technology object

      Add a new axis technology object.

      Open the configuration "Hardware interface" > "Drive".

      Select the "PROFIdrive" entry from the "Drive type" drop-down list.

      Select a drive axis of the PROFINET drive unit from the "Drive" list.
      Only drives for which you have configured a suitable PROFIdrive frame are available for selection. You can find out which PROFIdrive frames are supported by the SIMATIC Drive Controller in the S7?1500T Motion Control function manuals.

      Using the "Device configuration" button, you can switch to the drive device view, for example, to configure drives or set other PROFIdrive frames (for example 39x frame for the X122/X132 IOs of a CU320?2).

    Setting the clock system

    You have configured an external drive as isochronous on PROFINET using the example of the SINAMICS S120 CU320?2 PN. Next, set the clock system.

    Choose between independent and coupled isochronous mode.

    Set the required send clock.

    Assign the "MC Servo" OB the clock system of the PROFINET interface X150.


    上海騰希電氣技術(shù)有限公司專注于西門子PLC,V90伺服,V20變頻器等, 歡迎致電 13681875601

  • 詞條

    詞條說明

  • OPC 程序報(bào)警編輯器

    OPC 程序報(bào)警編輯器常規(guī)OPC 程序報(bào)警編輯器適用于 V14 及較高版本的 OPC 服務(wù)器。這可幫助您在 PC 站或 OPC 服務(wù)器與 S7-1500/S7-1500S 之間組態(tài) S7 連接的 OPC 程序報(bào)警,以便用戶特定視圖中的顯示對(duì)應(yīng)于您的工廠拓?fù)?。同時(shí),可以在用戶特定視圖中添加、重命名或刪除區(qū)域、源和條件,而且也可以使用不同語言對(duì)其進(jìn)行管理。根據(jù) STEP 7 項(xiàng)目的樹結(jié)構(gòu),對(duì)默認(rèn)視圖中

  • 屬性和對(duì)象過濾器的使用示例

    在項(xiàng)目中搜索的示例屬性和對(duì)象過濾器的使用示例搜索編輯器在“限制搜索范圍”(Limit Search To) 區(qū)域提供過濾器,用以將搜索范圍限制為特定屬性或?qū)ο?。?jǐn)記以下機(jī)制:如果未激活任何過濾器,則將在所設(shè)置的搜索區(qū)域內(nèi)能夠搜索到的全部對(duì)象和屬性中搜索該搜索條目。如果激活過濾器,則只針對(duì)所選屬性或?qū)ο筮M(jìn)行搜索。屬性和對(duì)象過濾器的使用示例:搜索名為“Motor1”的對(duì)象:輸入搜索條目并激活過濾器“名

  • 組態(tài)安全功能 選項(xiàng)

    選項(xiàng)在此頁面*分配新密碼時(shí)將使用的密碼策略。說明密碼策略 (Password Policy)顯示當(dāng)前正在使用的密碼策略新密碼策略 (New Password Policy)從該下拉列表中選擇所需的設(shè)置。-?高密碼長度:至少 8 個(gè)字符,較長 128 個(gè)字符至少 1 個(gè)大寫字母至少 1 個(gè)特殊字符至少 1 個(gè)數(shù)字-?低密碼長度:至少 6 個(gè)字符,較長 128 個(gè)字符

  • 將更改保存到與 Teamcenter 相連的全局庫中

    將更改保存到與 Teamcenter 相連的全局庫中要求需滿足以下要求:TIA Portal 已連接 Teamcenter。全局庫以“讀/寫”模式打開。所選擇的全局庫已連接到 Teamcenter 且進(jìn)行了更改。全局庫不支持多選。提示請(qǐng)注意以下事項(xiàng):TIA Portal 與 Teamcenter 之間無連接時(shí),“Teamcenter > 保存”(Teamcenter > Save) 命

聯(lián)系方式 聯(lián)系我時(shí),請(qǐng)告知來自八方資源網(wǎng)!

公司名: 上海騰希電氣技術(shù)有限公司

聯(lián)系人: 田禮科

電 話: 021-37660026

手 機(jī): 13681875601

微 信: 13681875601

地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號(hào)4樓

郵 編:

網(wǎng) 址: shtxjd.cn.b2b168.com

八方資源網(wǎng)提醒您:
1、本信息由八方資源網(wǎng)用戶發(fā)布,八方資源網(wǎng)不介入任何交易過程,請(qǐng)自行甄別其真實(shí)性及合法性;
2、跟進(jìn)信息之前,請(qǐng)仔細(xì)核驗(yàn)對(duì)方資質(zhì),所有預(yù)付定金或付款至個(gè)人賬戶的行為,均存在詐騙風(fēng)險(xiǎn),請(qǐng)?zhí)岣呔瑁?
    聯(lián)系方式

公司名: 上海騰希電氣技術(shù)有限公司

聯(lián)系人: 田禮科

手 機(jī): 13681875601

電 話: 021-37660026

地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號(hào)4樓

郵 編:

網(wǎng) 址: shtxjd.cn.b2b168.com

    相關(guān)企業(yè)
    商家產(chǎn)品系列
  • 產(chǎn)品推薦
  • 資訊推薦
關(guān)于八方 | 八方幣 | 招商合作 | 網(wǎng)站地圖 | 免費(fèi)注冊(cè) | 一元廣告 | 友情鏈接 | 聯(lián)系我們 | 八方業(yè)務(wù)| 匯款方式 | 商務(wù)洽談室 | 投訴舉報(bào)
粵ICP備10089450號(hào)-8 - 經(jīng)營許可證編號(hào):粵B2-20130562 軟件企業(yè)認(rèn)定:深R-2013-2017 軟件產(chǎn)品登記:深DGY-2013-3594
著作權(quán)登記:2013SR134025
Copyright ? 2004 - 2024 b2b168.com All Rights Reserved